Posted On May 30, 2019 By In Ewave, Sensors and Wireless, Telaire/Amphenol And 164 Views

T3000 Series Telaire Range of CO2 Sensors for Harsh Environments

Telaire

T3000 Series
Telaire Range of
CO2 Sensors for Harsh Environments

 
T3000 SeriesTelaire T303x Series is a range of Carbon Dioxide (CO2) Sensors designed to meet the specific needs of customers who require measuring CO2 in harsh or difficult environments. Based on a series of modules, the casing offers a number of combinations to meet the needs of range, supply voltage, and output type in various applications. These devices are offered in a IP rated housing and fully compensated digital (I2C) output configurations.
 
Features:
Sensing Method Non-Dispersive Infrared (NDIR), single or dual wavelength
Power Supply Requirements 15 – 15Vdc ±10%
24 – 18-30 VAC RMS, 50/60 Hz, or 18 to 42 VDC, polarity protected
Power Consumption Typical 0.7 W at nominal voltage of 24V AC RMS
Resolution Minimum 10-bit or analog equivalent
Accuracy
Single Wavelength
(0~2,000 ppm as example)
  • 400-1250 ppm ±30 ppm or 3% of reading, whichever is greater*,**
  • 1250-2000 ppm ±5% of reading + 30ppm *, **

*Tolerance based on span gas of ±2%
** ABC Logic not deactivated

Accuracy
(0~2,000ppm range as example)
75 ppm or 10% of reading, whichever is greater
Accuracy
Dual Wavelength
(0~200,000ppm range as example)
  • ±5% of reading or ±0,3 vol% CO2 (whichever is larger) at 0 – 20 vol% CO2 and 0°C to +25°C

At 25°C to 50°C additional ±0,1% of reading or ±0,01 vol% CO2 (whichever is larger) per °C

Working Temperature 0° to +50°C (measures within tolerance)
Operating Temperature -30° to +50°C (Sensor Is Powered)
Storage Temperature -40° to +70°C
RH Range 0% to 99% RH (non-condensing)
Digital Output
  • Modbus over RS485
  • UART
Analog Output
  • 0 to 5 V
  • 0 to 10 V
  • 4 to 20mA

*Digital to Analog Error ±1%

 
Telaire Offers 6 Different Versions of the T303X Series:
T3031-2-2K-24-P Industrial CO2 Sensor, Dual Channel, 0 – 2000 PPM, 0 to 10 VDC o/p, Potted
T3031-2-5K-24-P Industrial CO2 Sensor, Dual Channel, 0 – 5000 PPM, 0 to 10 VDC o/p, Potted
T3031-2-10K-24-P Industrial CO2 Sensor, Dual Channel, 0 – 10,000 PPM, 0 to 10 VDC o/p, Potted
T3032-2-5K-24-P Industrial CO2 Sensor, Dual Channel, 0 – 5000 PPM, 4 to 20 mA o/p Potted
T3032-2-10K-24-P Industrial CO2 Sensor, Dual Channel, 0 – 10,000 ppm, 4 to 20 mA o/p Potted
T3032-2-20K-24-P Industrial CO2 Sensor, Dual Channel, 0-20,000 PPM,4 to 20 mA o/p Potted
 
About Telaire/Amphenol
TELAIRE/Amphenol provides world leading low-cost infrared gas(CO2)sensing technology addressing a wide variety of HVAC (Commercial & Residential, Industrial, Automotive, Appliance, and Medical applications.
About Component Distributors Inc.
Component Distributors, Inc. (CDI) is a value-added distributor of high-performance LED, power, rf & microwave, wireless and sensor component technologies. CDI distributes globally and provides local application support and customer service across the Americas. CDI delivers cutting edge power electronics by wrapping application support, development tools and design services around high performance products from industry leading manufacturers.